Kyoritsu 2433 Leakage Clamp Meters
Frequency Selector Switch to eliminate the effect of harmonics.
Three AC current ranges:40mA/400mA/400A.
Resolution 0.01mA.
| AC A (50/60Hz) | 40/400mA/400A %rdgdgt (40/400mA) %rdgdgt (0 - 350A) %rdg (350.1 - 399.9A) |
|---|---|
| AC A (WIDE) | 40/400mA/400A %rdgdgt [50/60Hz], .5%rdg0dgt [20Hz - 1kHz] (40/400mA) %rdgdgt [50/60Hz], .5%rdg0dgt [40Hz - 1kHz] (0 - 350A) %rdg [50/60Hz], %rdg [40Hz - 1kHz] (350.1 - 399.9A) |
| Maximum circuit voltage | 600V AC/DC (between line/neutral) 300V AC/DC (against earth) |
| Conductor size | 40mm max. |
| Frequency response | 20Hz - 1kHz (40Hz - 1kHz:400A) |
| Effect of External Stray Magnetic Field | 10mA AC approx. in proximity to a 15mm-dia conductor carrying 100A AC |
| Safety Standard | IEC 61010-1 CAT III 300V Pollution Degree 2 IEC 61010-2-032 |
| Response Time | Approx. 2 seconds |
| Power source | Two R03 or equivalent (DC1.5V) batteries |
| Dimensions | 185(L) 81(W) 32(D)mm |
| Weight | 270g approx. |
| Included Accessories | 9097 (Carrying Case) R03 (1.5V) 2 Instruction Manual |
Customers who bought this product also bought