Gossen Metrawatt PRO-TYP II Test Adapter for Charging Stations
Single and 3-Phase Test Adapter for Testing for the Effectiveness of Protective Measures at Electrical Charging Stations with the Profitest Master,
Simulating Fictitiously Connected Electric Vehicles and Simulating the
Current-Carrying Capacity of Cord Sets per IEC 61851-1
- Vehicle Simulation (CP)
Vehicle states A through E are selected with a rotary switch.
- Cable Simulation (PP)
The various codings for charging cables with 13, 20, 32 and 63 A, as well as “no cable connected”, can be simulated with the help of a rotary switch.
- Fault Simulation
Simulation of a short-circuit between CP and PE by means of a rotary switch
- Indication of Phase Voltages via LEDs
Depending on the charging station, either one or three phases can be active.
Vehicle Simulation (CP):
States A, B, C, D and E can be simulated in accordance with IEC 61851. The various vehicle states are selected by means of a rotary switch.
| State A | No vehicle connected |
| State B | Vehicle connected, but not ready for charging |
| State C | Vehicle connected and ready for charging without venting |
| State D | Vehicle connected and ready for charging with venting |
| State E | Error – short circuit between CP and PE via internal diode |
Cable Simulation (PP)
The various codings for charging cables with 13, 20, 32 and 63 A can be simulated. It’s also possible to simulate the “no cable” state.
The various charging cables are simulated by connecting different resistances between PP and PE with the help of a rotary switch. The following values are possible in accordance with IEC 61851:
| No cable | 0 Ω |
| 13 A cable | 1,5 kΩ |
| 20 A cable | 680 Ω |
| 32 A cable | 220 Ω |
| 63 A cable | 100 Ω |